SAFE OPERATING PROCEDURE
Touchscreen Driver Software Procedure
Subject
:
19” Touchscreen Driver Software Procedure
Name and
number of
UPGRADE
Page
19 of
21
19
Touchscreen
the touchscreen to the LCD.
____6.2
• This calibration step must be
carried out when the
touchscreen is fully mounted
into its final housing in front of
the LCD.
____6.3
• To launch a calibration click
on the Calibrate button
located in the bottom left
hand corner of the UPDD
console.
NOTE: All calibrations should be performed at the level of sight as intended use.
____6.4
• Change the number of
calibration points from 9 to
25. Single click on calibrate.
This will launch a 25 point
calibration sequence. This
will increase the timeout to 45
seconds, allowing more time
for callibration.
____6.5
• Having touched the first point
the second point will be
displayed. Sequentially touch
all 25 points as they are
displayed on the screen, as
shown in Figure 1-13.
____6.6
• Important – The accuracy of
the calibration will directly
depend on how accurately
you touch the center of each
point displayed on the screen.
____6.7
• Having touched all twenty five
(25) points, a Confirm
calibration box will appear on
the screen. If you feel the
calibration has been correctly
executed then press the